© ACME 2012
Made with Xara
Major Works Completed by
Australian Construction & Maintenance Engineers Pty Ltd
M5 Stage 1 Replacement
Construction of approx 2400 metres of DN750MSCL & DN375MSCL
Client - Yarra Valley Water
Completed - January 2012
Relocation of Melb. Watermains for Peninsula Link
Relocation of exisiting twin Melbourne Water DN900 water mains crossing freeway reserve onto a 2 span
concrete bridge.
Client - Abigroup
Completed - February 2012
Construction of M26 Watermain in Epping
Construction of 1,123 metres of 350D PN16 PE pipe.
Client - Yarra Valley Water
Completed - December 2011
Construction of DN900 & DN375 Watermain for South Morang Rail Project
Construction of 145 metres of MSCL DN900 & 146 metres of DN375 watermain.
Client - John Holland
Completed - November 2011
Construction of M686 DN600 Link main & M679 DN900 Mernda Reservoir Outlet Main, South Morang
Construction of 730 metres of DN900 MSCL pipe and approx. 1200 metres of DN600 MSCL pipe and
associated pipework.
Client - Yarra Valley Water
Completed - January 2010
Donnellys Pipeline & Weir Modification Works Healesville
Construction of 450 metres of 450 PN 6.3 PE 100 pipe and associated works including fabrication and
installation of 450 Penstock Gate.
Client - Yarra Valley Water
Completed - January 2010
Construction of Point Cook Distribution Main
Construction of 2,210 metres of MSCL DN900 watermain and associated works.
Client - City West Water
Completed - December 2009
M71 & M43 Warrigal Rd Main Replacement Stage 3
Construction of approx. 2630 metres of DN750 MSCL, DN450 MSCL from High St Road to Burwood Highway.
Client - Yarra Valley Water
Completed - December 2008
M104B Morang Outlet Watermain Replacement Stage 5 Melbourne Water
Construction of approx. 2242 metres of DN600 MSCL along Grimshaw St, Watsonia Rd, High St and Black St.
Client - Melbourne Water
Completed - September 2008
Supernatant Pump Station No 4 Upgrade Works Melbourne Water
Install pump, remove and replace existing pit, construct Steel A frame to support elevated pipework.
Client - Melbourne Water
Completed - June 2008
Sludge Drying pan, Sludge and Supernatant Pipework Upgrade - Eastern Treatment Plant
Upgrade of digested sludge conveyance system & digested sludge distribution system, modifications to
existing supernatant drainage system, construction of new overflow.
Client - Melbourne Water
Completed - April 2008
Construction of Watermain Relocation Monash Freeway Dandenong
Relocation of approx. 213m of 450mm OD MSCL main & 1 No 210m of 972mm OD MSCL Pipeline under
Maroondah Hwy in vicinty of proposed Eastlink.
Client - Thiess John Holland
Completed - November 2005
Construction of Watermain Relocation Maroondah Hwy Ringwood
Relocation of 2 No 220m of 1200mm OD MSCL & 1 No 210m of 972mm OD MSCL Pipeline under Maroondah
Hwy in vicinity of proposed Eastlink.
Client - Thiess John Holland
Completed - November 2005
Construction of Watermain Relocation Halton Rd Dandenong
Relocation of approx. 250m of SEWL 1150mm OD MSCL pipeline in vicinty of proposed Eastlink.
Client - Thiess John Holland
Completed - October 2005